SAT-QF150 model
Breathing Valve Set-Pressure Calibration Bench
It is used to accurately verify the positive and negative opening pressures of the breather valve and to conduct sealing tests, thereby ensuring vessel safety.
Technical Specifications
- Maximum verification diameter: DN150mm
- Verify the respiratory value range: -50.0 kPa to +50 kPa
- Applicable ambient temperature: -20°C to 60°C
- Applicable to flanged and threaded breather valves.
- Medium: Dry, clean compressed air or nitrogen
- Pneumatic clamping structure
- Verification accuracy: ±0.4%
Equipment Advantages
- Given the wide size range and susceptibility to deformation of breather valves, the pressure‑setting test bench for breather valves employs an eccentric‑disc‑type pressure foot instead of a conventional clamping foot. This design accommodates variations in flange dimensions, and the larger contact area of the eccentric‑disc‑type pressure foot helps prevent flange deformation.
- Due to the significant leakage of the breather valve, a larger-capacity air chamber suction structure has been specifically adopted.
- Pneumatic clamping mechanism, convenient and quick to operate;
- The equipment is made of stainless steel.
- A digital pressure gauge with positive and negative pressure readings, calibrated by a legally recognized metrology institution.
Attention
- The verification medium shall be nitrogen or clean compressed air, and the medium source shall be provided by the user.
- This equipment is not intended for use in verifying other valves.